<p>SMART2200NET intelligent line-interactive large tower UPS system protects servers, networking accessories and telecommunications equipment from blackouts, voltage fluctuations and transient surges. Large internal batteries offer 27 minutes half-load runtime and 11 minutes fully loaded. Runtime is expandable with optional BP24V28-2U (limit 1) and BP24V70-3U external battery packs. 2200VA/1700W power handling capability supports a variety of networking, telecom and other sensitive electronic applications. Includes six protected outlets. Supports remote monitoring of UPS and site power conditions via built-in RS-232 enabled monitoring port, plus standard UPS monitoring via two built-in contact closure ports. PowerAlert(R) UPS monitoring and unattended shutdown software is available via free download. Built-in audible alarm and front-panel LEDs indicate line power, battery power, battery charge level, load level, plus voltage regulation status. Network-grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges.</p><br /><br /><ul><li>UPC Code: 037332032041</li><li>UPS Type: Line-Interactive</li><li>Input Phase: Single-Phase</li><li>Rated input current (Maximum Load): 15A</li><li>Nominal Input Voltage(s) Supported: 120V AC</li><li>UPS Input Connection Type: 5-15P</li><li>Input Circuit Breakers: 20A</li><li>UPS Input Cord Length (ft.): 8</li><li>Recommended Electrical Service: 20A 120V</li><li>Input Cord Length (ft.): 8</li><li>Output Capacity (VA): 2200</li><li>Output Capacity (kVA): 2.2</li><li>Output Capacity (Watts): 1700</li><li>Output Capacity (kW): 1.7</li><li>Output Capacity Details: Output is reduced to 1200W maximum with 1-2 external battery packs and 800W maximum with 3 or more external battery packs</li><li>Power Factor: 0.8</li><li>Nominal Voltage Details: 120v nominal output in battery mode</li><li>Frequency Compatibility: 60 Hz</li><li>Output Voltage Regulation (Line Mode): -13% / +5%</li><li>Output Voltage Regulation (Battery Mode): +/- 5%</li><li>Load Management Receptacles: Two switchable single outlet 5-15R load banks</li><li>Output AC Waveform (AC Mode): Sine wave</li><li>Output AC Waveform (Battery Mode): PWM sine wave</li><li>Nominal Output Voltage(s) Supported: 110V; 115V; 120V</li><li>Output Receptacles: (6) 5-15R</li><li>Individually Controllable Load Banks: Yes</li><li>Runtime Full Load (min.): 11 min.</li><li>Runtime Half Load (min.): 27 min.</li><li>Expandable Runtime: Yes</li><li>External Battery Pack Compatibility: BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)</li><li>DC System Voltage (VDC): 24</li><li>Battery Recharge Rate (Included Batteries): Less than 9 hours from 10% to 90% (typical, full load discharge)</li><li>Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 87 to 140</li><li>Overvoltage Correction: Input voltages between 127 and 140 are reduced by 12%</li><li>Undervoltage Correction: Input voltages between 95 and 105 are boosted by 10%</li><li>Severe Undervoltage Correction: Input voltages between 87 and 94 are boosted by 22%</li><li>Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation; set of 4 rear-panel switches control system enable and contact closure port inverter shutoff commands</li><li>Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status</li><li>Audible Alarm: Audible alarm indicates power-failure and low-battery conditions</li><li>LED Indicators: 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status</li><li>UPS AC Suppression Joule Rating: 720</li><li>UPS AC Suppression Response Time: Instantaneous</li><li>EMI / RFI AC Noise Suppression: Yes</li><li>Primary Form Factor: Tower</li><li>Primary UPS Depth (mm): 318</li><li>Primary UPS Height (mm): 432</li><li>Primary UPS Width (mm): 229</li><li>Shipping Dimensions (hwd / in.): 13.75 x 16.50 x 22.50</li><li>Shipping Weight (lbs.): 82.16</li><li>UPS Housing Material: Polycarbonate</li><li>UPS Power Module Dimensions (hwd, in.): 17 x 9 x 12.5</li><li>UPS Power Module Weight (kg): 36.29</li><li>UPS Power Module Weight (lbs.): 80</li><li>Unit Weight (lbs.): 80.0000</li><li>Operating Temperature Range: 32? to 104?F (0? to 40?C)</li><li>Storage Temperature Range: 5? to 122?F (-15? to 50?C)</li><li>Relative Humidity: 0 to 95%, non-condensing</li><li>AC Mode BTU / Hr. (Full Load): 59</li><li>Battery Mode BTU / Hr. (Full Load): 867</li><li>AC Mode Efficiency Rating (100% Load): 99%</li><li>Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions; contact closure communications via two additional DB9 ports (3 total)</li><li>PowerAlert Software: For local monitoring via the UPS's built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert</li><li>Communications Cable: 3 DB9 cables included</li><li>Network Management Card Description: Network management not supported</li><li>Communications Interface: Contact closure; DB9 Serial</li><li>Transfer Time: 2-4 milliseconds</li><li>Low Voltage Transfer to Battery Power (Setpoint): 87</li><li>High Voltage Transfer to Battery Power (Setpoint): 140</li><li>Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported</li><li>High Availability UPS Features: Surge/noise protection</li><li>UPS Applications: Large Network</li><li>Product Certifications: CSA (Canada); NOM (Mexico); UL 1778</li><li>Product Compliance: RoHS; FCC Part 15 Class A (USA)</li><li>Product Warranty Period (Worldwide): 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.</li><li>Connected Equipment Insurance (U.S., Canada & Puerto Rico): $250,000 Ultimate Lifetime Insurance</li></ul>
1
Seller
8
In Stock
$1,321.40
From
Conditions available
New
Free members see each seller's price & contact details