Eaton
EATON TRIPP LITE SERIES SMARTONLINE 750VA 675W 120V DOUBLE-CONVERSION SINE WAVE
| details | OUTPUTOutput Volt Amp Capacity (VA) 750Output kVA Capacity (kVA) .75Output Watt Capacity (Watts) 675Output Capacity DetailsON LINE MODE: Maximum output capacity is reduced to 608 watts at 100V nominal FREQUENCY CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120/115/110V: 472 watts / 100V: 425 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) Power Factor0.9Crest Factor3:1Nominal Output Voltage(s) Supported100V 110V 115V 120V 127VNominal Voltage Details120V factory-default nominal voltageFrequency Compatibility50 / 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversionFrequency Compatibility DetailsON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup Output matches input frequency when +/-5Hz of nominal Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz. Output Voltage Regulation (Line Mode) +/- 2%Output Voltage Regulation (Economy Line Mode) +/- 10%Output Voltage Regulation (Battery Mode) +/- 3%Output Receptacles(6) 5-15RLoad Management ReceptaclesTwo switchable single-outlet 5-15R l INPUTRated input current (Maximum Load) 8ANominal Input Voltage(s) Supported100V AC 110V AC 115V AC 120V AC 127V ACNominal Input Voltage Description120V factory defaultUPS Input Connection Type5-15PInput Circuit Breakers15AUPS Input Cord Length (ft.) 10UPS Input Cord Length (m) 3.0Recommended Electrical Service15A 120VInput PhaseSingle-Phase BATTERYFull Load Runtime (min.) 4.3 min. (675w) Half Load Runtime (min.) 13.9 min. (337.5w) Expandable Battery RuntimeExtended runtime supported via optional external battery packsExternal Battery Pack CompatibilityBP24V15RT2U(limit 1) BP24V28-2U(limit 1) BP24V70-3U(multi-pack compatible) BP24V36-2US(multi-pack compatible) Expandable Runtime DescriptionSome external battery configurations require the use of Tripp Lites External Battery Configuration Software, see manual for detailsDC System Voltage (VDC) 24Battery Recharge Rate (Included Batteries) Less than 3 hours recharge to 90% (typical, full load discharge) Internal UPS Replacement Battery CartridgeRBC24V-LCDBattery AccessFront panel battery accessBattery Replacement DescriptionHot-swappable, user replaceable batteriesExpandable RuntimeYes VOLTAGE REGULATIONVoltage Regulation DescriptionOnline, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltagesOvervoltage CorrectionCorrects overvoltages to 150V (0-100% load) Undervoltage CorrectionCorrects undervoltages to 100V at full load (90V at 100V nominal) Severe Undervoltage CorrectionCorrects brownouts to 70V (70% load) 55V (33% load) USER INTERFACE, ALERTS CONTROLSFront Panel LCD DisplayFront panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional optionsSwitches2 switches control off/on power status and alarm-cancel operation 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration optionsAlarm Cancel OperationPower-fail alarm can be temporarily silenced using alarm-cancel switch silent mode alarm configuration option availableAudible AlarmAudible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditionsLED Indicators7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status SURGE / NOISE SUPPRESSIONUPS AC Suppression Joule Rating570UPS AC Suppression Response TimeInstantaneousUPS Dataline Suppression1 line TEL/DSL (1 in / 1 out) 10/100Base T EthernetEMI / RFI AC Noise SuppressionYes PHYSICALIncluded Mounting Accessory Description4 post rackmount installation accessories includedInstallation Form Factors Supported with Optional Accessories2 post rackmount(2POSTRMKITWM) Wallmount(2POSTRMKITWM) Tower(2-9USTAND) Primary Form FactorRackmountCooling MethodFanUPS Housing MaterialSteel ENVIRONMENTALOperating Temperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees CelsiusStorage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees CelsiusRelative Humidity0 to 95%, non-condensingAC Mode BTU / Hr. (Full Load) 256AC Economy Mode BTU / Hr. (Full Load) 173Battery Mode BTU / Hr. (Full Load) 439AC Economy Mode Efficiency Rating (100% Load) 93%Operating Elevation (ft.) 0-3000m / 0-10,000 ft. Audible Noise45 dBA at 1m front sideOperating Elevation (msnm) 0 - 3000 m COMMUNICATIONSCommunications InterfaceUSB (HID enabled) DB9 Serial Contact closure EPO (emergency power off) Slot for SNMP/Web interfaceNetwork Management CardsSNMPWEBCARD TLNETCARD WEBCARDLX MODBUSCARD Network Monitoring Port DescriptionSupports detailed monitoring of UPS and site power conditions DB9 port supports RS232 and contact closure communicationsPowerAlert SoftwareFor local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralertCommunications CableUSB and DB9 cabling includedWatchDog CompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFERTransfer TimeZero (0 milliseconds) in double-conversion mode 4 milliseconds economy modeLow Voltage Transfer to Battery Power (Setpoint) 100V at full load (90V full load at 100V nominal setting) 70V at 70% load 55V at 33% loadHigh Voltage Transfer to Battery Power (Setpoint) 150 SPECIAL FEATURESCold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supportedHigh Availability UPS FeaturesAutomatic inverter bypass Hot swappable batteriesGreen Energy-Saving FeaturesHigh efficiency economy mode operation Individually controllable load banks Schedulable daily hours of economy mode operation CERTIFICATIONSUPS CertificationsTested to UL1778 (USA) Tested to CSA (Canada) Meets FCC Part 15 Category B (EMI) ROHS (Restriction of Hazardous Substances) Item Dimension (L inchxW inchxH inch)20 x 24 x 9Weight 48.40lbWarranty Information2-year limited warranty |
| Seller | Condition | Qty | Price | Location | Updated | Action | |
|---|---|---|---|---|---|---|---|
|
Aztek Computers
VAR |
Refurbished | 8 | $1,592.50 | Frisco, TX | Mar 18 |